电线ul1571和ul1095的区别?

最明显的区别就是1571额定电压是30V,最小导体可做到50AW.绝缘材料可以有PVC,SRPVC,XLSRPVC,而1095是300V.最小导体只能做到30AWG,绝缘只有PVC可做. 1095的绝缘厚度大于1571的. Rating 80 deg C, 30 Vac, Horizontal flame. Condu

问答分类 电线 区别 网友:水云间秋忆 来源:装修问答网 2024-06-29

最新回答

  • 1、最明显的区别就是1571额定电压是30V,最小导体可做到50AW.绝缘材料可以有PVC,SRPVC,XLSRPVC,而1095是300V.最小导体只能做到30AWG,绝缘只有PVC可做. 1095的绝缘厚度大于1571的. Rating 80 deg C, 30 Vac, Horizontal flame. Conductor 50 AWG minimum. Solid or stranded. Insulation Extruded PVC, SRPVC, foamed PVC, foamed SRPVC, XLPVC, XLSRPVC, foamed XLPVC or foamed XLSRPVC, 2 mils minimum thickness at any point, 100 mils maximum thickness. Rating 80 deg C, 300 Vac, Horizontal flame. Conductor 30 AWG - 16 AWG, solid or stranded. Insulation Extruded PVC, 12 mils minimum average thickness, 9.5 mils minimum thickness at any point.

相关问题

电线ul1571和ul1095的区别

  • 最明显的区别就是1571额定电压是30V,最小导体可做到50AW.绝缘材料可以有PVC,SRPVC,XLSRPVC,而1095是300V.最小导体只能做到30AWG,绝缘只有PVC可做. 1095的绝缘厚度大于1571的. Rating 80 deg C, 30 Vac, Horizontal flame. Conductor 50 AWG minimum. Solid or stranded. Insulation Extruded PVC, SRPVC, foamed PVC, foamed SRPVC, XLPVC, XLSRPVC, foamed XLPVC or foamed XLSRPVC, 2 mils minimum thickness at any point, 100 mils maximum thickness. Rating 80 deg C, 300 Vac, Horizontal flame. Conductor 30 AWG - 16 AWG, solid or stranded. Insulation Extruded PVC, 12 mils minimum average thickness, 9.5 mils minimum thickness at any point.